1. BC2A/90  – SMF extract   on  02.MM.20YY

2. BC1B/93  – SMF extract   on  02.MM.20YY

3. BC3A/92  – SMF common extract  and SCRT report for 3 LPAR’s  on  02.MM.20YY

4. Receive  SCRT report for 3 LPAR’s    from MF on PC

5 . Submit    SCRT  report for 3 LPAR’s    from PC to IBM LMS

6. Confirmation Report  from IBM/LMS for the received SCRT  report

7. BC2A/90  – SMF old save  files backup, delete, restore

8. BC3A/92  – SMF old save  files backup, delete, restore

9. BC1B/93  – SMF old save  files backup, delete, restore

           SCRT  monthly Report  processing  of  SMF data   for 3 LPARs of Mainframe  including SMF dump jobs  and link to  IBM/LMS  are  described below. For each LPAR the summary  SMF file is copied  after  the 01 day of the current  month on a save file, the current summary file is emptied  to continue collecting the  SMF data and   extract of SMF  records TYPE(70,89) from saved SMF files for the reporting period from 02 day of previous month  to 01 day of current month  inclusive are  performed on a  disk volume  common for all 3 LPAR’s.  Next  a new  common extract  is performed  for   SMF  records TYPE(70,89) using  the 3 LPAR extracts and the common extract is used as  input to produce the final common SCRT report for the whole  Mainframe in library member HLQ.SCRTTOOL.CSV(#836093F). The library member file #836093F is transfered  from  the common disk volume of MF to  PC in character format   as file  ready to be submitted  to  the IBM/LMS  application link between the 2nd and the 9th day of the month inclusive.  After successfully submitting  the SCRT report  a  Confirmation Report  from IBM/LMS  is received for the applied  minimized  Software Charges of  the reporting period.

          The final operations include backup on a separate save SMF  tape  for each LPAR the   previous  SMF summary files, deletion  the  old ones and restore from tape if necessary.

           1. BC2A/90  – SMF extract   on  02.MM.20YY

   BC2A/90  – summary SMF file copy on  disk  save file, empty summary, extract saved files.

               1.1. Job FCOSMF02 /BC2A.ZOS140.OPER.LIB.CICS10(FCOSMF02)/ after   02.MM.20YY  –   copy summary (collection) SMF  file  IPOSAV.SMFDUMPW  to   KCI08.SMF.D051112 (including 01.11.2012) and    keeping  previous  KCI08.SMF.D031012 (including 02.10.2012)  

 //STEP04  EXEC PGM=ADRDSSU,REGION=0M,TIME=1440 PARM=’TYPRUN=NO

//SYSPRINT DD  SYSOUT=*

//SYSIN    DD  *

   COPY DATASET(INC(      –

    IPOSAV.SMFDUMPW      –

   )) –

   RENAMEU(IPOSAV.SMFDUMPW      –

   KCI08.SMF.D051112)  –

               1.2. Job SMFWEMPT  /BC2A.ZOS140.OPER.LIB.CICS10(SMFWEMPT)/ –  empty summary (collection) SMF  file  IPOSAV.SMFDUMPWto continue collecting new  SMF data  with DUMPXY for the next month.(/d smf  – care the active MAN  file is less than 90%)

 //DMPSMF5 EXEC PGM=IEBGENER,REGION=768K,COND=(4,LT)

//SYSPRINT DD  SYSOUT=*

//SYSIN    DD  DUMMY

//SYSUT1   DD  DSN=NULLFILE,DCB=IPOSAV.SMFDUMPW

//SYSUT2   DD  DSN=IPOSAV.SMFDUMPW,

//             DISP=OLD

               1.3. Job SMFEXTR7 /BC2A.ZOS140.OPER.LIB.CICS10(SMFEXTR7)/ –  extract saved  file KCI08.SMF.D031012 and last copied file  KCI08.SMFRF.D051112 (repared fixed)  to produce file HLQ.SMFEXTR.FEB90 for OUTDD(OUTDD1,TYPE(70,89))  and DATE (2012276,2012306 –  extract for period  02.10 to  01.11.2012)  on common disk volume for 3 LPAR’s VOL=SER=SP1789.

//SMFDUMP  EXEC PGM=IFASMFDP

//INDD1     DD DSN=KCI08.SMF.D031012,DISP=SHR

//INDD2     DD DSN=KCI08.SMFRF.D051112,DISP=SHR

//OUTDD1    DD DSN=HLQ.SMFEXTR.FEB90,UNIT=(3390,1),

//             DISP=(NEW,CATLG,DELETE),VOL=SER=SP1789,

//             SPACE=(TRK,(700,600))

//SYSPRINT  DD SYSOUT=A

//SYSIN     DD *

   INDD(INDD1,OPTIONS(DUMP))

   INDD(INDD2,OPTIONS(DUMP))

   OUTDD(OUTDD1,TYPE(70,89))

   DATE(2012276,2012306)            

   START(0000)

   END(2400)

 Verify SP1789 is online for BC2A/90 with TSO/ISPF:

/D U,,,1789,1

IEE457I 14.15.37 UNIT STATUS 317

UNIT TYPE STATUS        VOLSER     VOLSTATE

1789 3390 O             SP1789     PRIV/RSDNT

           2. BC1B/93  – SMF extract   on  02.MM.20YY

   BC1B/93  – summary SMF file copy on  disk  save file, empty summary, extract saved files .

               2.1. Job COPYDSN2 /BC1B.ZOS140.OPER.LIB(COPYDSN2)/ after   02.MM.20YY  –   copy summary (collection) SMF  file  IPOSAV.SMFDUMPW  to   SMFDUMPW.D051112 (including 01.11.2012) and    keeping  previous   SMFDUMPW.D031012 (including 02.10.2012) on VOL=SER=SP0659

               2.2. Job SMFWEMPT  /BC1B.ZOS140.OPER.LIB(SMFWEMPT)/ –  empty summary (collection) SMF  file  IPOSAV.SMFDUMPWto continue collecting new  SMF data  with DUMPXY for the next month.(/d smf  – care the active MAN  file is less than 90%)

               2.3. Job SMFEXTR9 /BC1B.ZOS140.OPER.LIB(SMFEXTR9)/ –  extract from VOL=SER=SP0659 the old saved  file SMFDUMPW.D031012 and last saved  file  SMFDUMPW.D051112 to produce file HLQ.SMFEXTR.FEB93 on VOL=SER=SP1789 for OUTDD(OUTDD1,TYPE(70,89))  and DATE (2012276,2012306 –  extract for period  02.10 TO 01.11.2012)  on common disk volume for 3 LPAR’s VOL=SER=SP1789.

Verify SP1789 is online for BC1B/93 with TSO/ISPF:

/D U,,,1789,1

IEE457I 14.15.37 UNIT STATUS 317

UNIT TYPE STATUS        VOLSER     VOLSTATE

1789 3390 O             SP1789     PRIV/RSDNT

            3. BC3A/92  – SMF common extract  and SCRT report for 3 LPAR’s  on  02.MM.20YY

   BC3A/92  – summary SMF file copy on  disk  save file, empty summary, extract saved files.

               3.1. Job COPYSMF2 /BC2A.ZOS140.OPER.LIB(COPYSMF2)/ after   02.MM.20YY  –   copy summary (collection) SMF  file  IPOSAV.SMFDUMPW  to   KCI08.SMF.D051112 (including 01.11.2012) and    keeping  previous repared  KCI08.SMFR.D031012 (including 02.10.2012)  

               3.2. Job SMFWEMPT  /BC2A.ZOS140.OPER.LIB(SMFWEMPT)/ –  empty summary (collection) SMF  file  IPOSAV.SMFDUMPWto continue collecting new  SMF data  with DUMPXY for the next month.(/d smf  – care the active MAN  file is less than 90%)

               3.3. Job PATTRSNW /BC2A.ZOS140.OPER.LIB(PATTRSNW)/ – rename duplicate  SYSIDS (PARM=’/BC2A*BC3A‘) of some records from DSN=KCI08.SMF.D051112 to DSN=KCI08.SMFR.D051112.

 //    EXEC PGM=LOADER,PARM=’/BC2A*BC3A’

//SYSLOUT DD    SYSOUT=*

//SYSUT1  DD    UNIT=VIO,SPACE=(TRK,(2,2))

//* CHANGE THE FOLLOWING TO YOUR INPUT SMF DATASET

//SMFIN   DD    DISP=SHR,DSN=KCI08.SMF.D051112

//* THIS WILL CONTAIN THE INPUT DATA SET WITH THE SYSID CHANGED

//SMFOUT  DD    DSN=KCI08.SMFR.D051112,DISP=(,CATLG,DELETE),UNIT=SYSDA,

//   BLKSIZE=8192,SPACE=(TRK,(23250,600))                               

                3.4. Job SMFEXT8 /BC2A.ZOS140.OPER.LIB(SMFEXT8)/ –  extract saved  file KCI08.SMFR.D031012 and last renamed  file  KCI08.SMFR.D051112 to produce file HLQ.SMFEXTR.FEB92 for OUTDD(OUTDD1,TYPE(70,89))  and DATE (2012276,2012306 –  extract for period  02.10 TO 01.11.2012)  on common disk volume for 3 LPAR’s VOL=SER=SP1789.

Verify SP1789 is online for BC2A/92 with TSO/ISPF:

/D U,,,1789,1

IEE457I 14.15.37 UNIT STATUS 317

UNIT TYPE STATUS        VOLSER     VOLSTATE

1789 3390 O             SP1789     PRIV/RSDNT

                3.5. Job SMFEXT8X /BC2A.ZOS140.OPER.LIB(SMFEXT8X/ –  extract the following all previous extracted files from  the common disk volume for 3 LPAR’s VOL=SER=SP1789:

//SMFDUMP  EXEC PGM=IFASMFDP

//INDD1   DD DSN=HLQ.SMFEXTR.FEB92,DISP=OLD

//INDD2     DD DSN=HLQ.SMFEXTR.FEB90,DISP=SHR,

//             UNIT=(3390,1),VOL=SER=SP1789

//INDD3     DD DSN=HLQ.SMFEXTR.FEB93,DISP=SHR,

//             UNIT=(3390,1),VOL=SER=SP1789

//OUTDD1    DD DSN=HLQ.SMFEXTR.FEBXX,UNIT=(3390,1),VOL=SER=SP1789,

//   SPACE=(TRK,(700,600)),DISP=(NEW,CATLG,DELETE)                

 

DSN=HLQ.SMFEXTR.FEB92,DISP=OLD – for LPAR BC3A/92

DSN=HLQ.SMFEXTR.FEB90,DISP=SHR,

      UNIT=(3390,1),VOL=SER=SP1789     –  for LPAR BC2A/90

DSN=HLQ.SMFEXTR.FEB93,DISP=SHR,

       UNIT=(3390,1),VOL=SER=SP1789   –  for LPAR BC1B/93

Produced is the  file HLQ.SMFEXTR.FEBXX for OUTDD(OUTDD1,TYPE(70,89))  and DATE (2012276,2012306 –  common extract for period  02.10 TO 01.11.2012)  on the  common disk volume for 3 LPAR’s VOL=SER=SP1789.

               3.6. Job SCRTTOOL /BC2A.ZOS140.OPER.LIB0(SCRTTOOL)/ – processes the common SMF extract data file for 3 LPAR’s HLQ.SMFEXTR.FEBXX from VOL=SER=SP1789 and produce report in library member  HLQ.SCRTTOOL.CSV(#836093F) on common disk volume VOL=SER=SP1789 ready to   send  to IBM/LMS site.

 //SCRT     EXEC  PGM=LOADER

//SYSPRINT DD    SYSOUT=*

//SYSLOUT  DD    SYSOUT=*

//* FOR SEQUENTIAL OUTPUT (ALL CPCS IN ONE DS)

//* CHANGE SPACE PARAMETER TO SPACE=(TRK,(15,15))

//OUTPUT   DD    DISP=(,CATLG),DSN=HLQ.SCRTTOOL.CSV,

//            SPACE=(TRK,(15,15,15)),UNIT=(3390,1),VOL=SER=SP1789

//SMF      DD    DISP=SHR,DSN=HLQ.SMFEXTR.FEBXX,

//        UNIT
=(3390,1),VOL=SER=SP1789

           4. Receive  SCRT report for 3 LPAR’s    from MF on PC 

   Get z/OS  member file HLQ.SCRTTOOL.CSV(#836093F) in character format  from  common disk volume VOL=SER=SP1789 of MF to  d:\admin\sysprog\ibm_tool\smf_process on PC file  hlq92.scrttoor.d081112.csv as follows:

– Logon to BC2A/92 on session ‘B’

– On TSO “b” session –  Enter –    p.6  (ISPF Command Shell)

– From DOS prompt on PC – Enter D:

D: cd admin\sysprog\ibm_tool\smf_process – /copy from here and paste to DOS prompt/

receive  hlq92.scrttoor.d081112.csv b: HLQ.SCRTTOOL.CSV(#836093F) ascii crlf /copy from here and paste to DOS prompt/

          5 . Submit    SCRT  report for 3 LPAR’s    from PC to IBM LMS

               5.1. Access the IBM/LMS  application link

D:\admin\sysprog\ibm_tool\smf_process\hlq92.scrttoor.d081112.csv is sent to IBM using

the Data Submission IBM/LMS  application link as follows:

http://www.ibm.com/software/lms

After entering the site the following appears:

License management support

Welcome to the license management support application.

This application will assist you in submitting software use data to IBM.

Customers submitting SCRT or FCRT data for z/OS, z/TPF and/or z/VSE, please proceed to sign in.

IBM employee sign in using your IBM intranet ID and password.

Select sign in to enter the application.

Customer sign in

               5.2. Sign in  the IBM/LMS  application link

– Click  on Customer sign in

Enter your ID and PW:

– ID = xxxxxx

– PW = yyyyyy

The following screen appears:

IBM License management support

Welcome to the license management support application. The following functions are available:

Data submission

Submit software use data to IBM or view previously submitted data.

               5.3. Data submission in  the IBM/LMS  application link

– Click on Data submission.

The following screen appears:

IBM data submission

[String not found(body, Text1)]

Submit your current SCRT or FCRT data

–       Click on Submit your current SCRT or FCRT data.

The following screen appears:

Submit your current SCRT or FCRT data

Top of Form

To import your SCRT or FCRT report(s) type in the path:\filename or select it with the “browse function“.

After the SCRT or FCRT report has been imported, you will have the opportunity to provide additional information before final submission.

Please note:

  • SCRT or FCRT reports must be submitted between the 2nd and the 9th day of the month inclusive.
  • If the data collected during the reporting period covers less than 95% of the period, you will be prompted to provide an explanation.

–       SCRT or FCRT report file*required  – press Browse and choose the file hlq92.scrttoor.d081112.csv in directory  D: cd admin\sysprog\ibm_tool\smf_process

The name hlq92.scrttoor.d081112.csv of the file to be send appears.

The text Continue appears:

– Click on  Continue

The following screen appears:

Bottom of Form

Submit your current SCRT or FCRT data

 Data saved as ‘Work in progress’ is available for submission.

You can select any system not yet submitted by ‘clicking’ on its number. You will have the opportunity to update your sub-capacity or full-capacity information before submitting it. After each report submission has been confirmed, the status field for that system will change to ‘Submitted’.

Systems

System

Customer

Customer name

 Status

Time stamp

83-6093F 644164000 xxxxxxxxxx      Work in progress     8Nov2012 16:01 UTC

– Click on  “System/83-6093” field to see the information to submit.

The following screen appears:

Submit your current SCRT or FCRT data

 

Please edit / update as needed for the machine 2066-0A1 83-6093F and select ‘continue’.

The ‘Customer/Submitter’ information requested below is required to process your sub-capacity or full-capacity transactions with IBM. This data will be used by us (or by others involved in fulfillment) to fulfill your requests. It may also be used to contact you for customer satisfaction surveys, market research or in connection with certain other related transactions such as notification of updates to the tool or process.

By clicking ‘submit’ you agree that IBM may process and retain your data for the purposes listed above in accordance with IBM’s data privacy policy.

2066-0A1 83-6093F

Customer/Submitter information

Machine details

Tool information

Tool release

% Data Collected for z/OS

Reporting period

 

Product summary information

MLC Product name Product ID

Tool MSU

Customer MSU

Customer comment
z/OS V1 5694-A01

3

   
CICS TS for OS/390 V2 5697-E93

2

   
IBM Enterprise Cobol for z/OS and OS/390 V3 5655-G53

3

 

                              

 Edit

Detailed Data Collection

LPAR Name System ID

Input Data Start

Input Data End

Report % Customer Comments (255 chars max)
BC1B BC1B 02 Aug 2012 – 09:00 01 Sep 2012 – 23:45

98.6%

   
BC2A BC2A 02 Aug 2012 – 13:03 01 Sep 2012 – 23:48

98.1%

   
BC3A BC3A 03 Aug 2012 – 08:03 01 Sep 2012 – 23:48

95.5%

   
CPC   02 Aug 2012 – 09:00 01 Sep 2012 – 23:48

98.6%

   

 

General

Type an overall comment here, if needed (max 255 characters)

Edit

– Click on  continue.

The following screen appears:

License management data submission – confirm page

 

Please confirm that the following data is to be submitted for the machine 2066-0A1 83-6093F

Control number 1347447911535 2066-0A1 83-6093F

Customer/Submitter information

Submitter name

Customer name

Submitter e-mail

Customer number

Submitter phone

Machine details

Machine type and model

Machine serial number

Machine rated capacity

Tool information

Tool release

20.2.0

% Data Collected for z/OS

Reporting period

2 Aug, 2012 – 1 Sep, 2012 inclusive (31 days)

98%

Product summary information

MLC Product name

Product ID

Tool MSU

Customer MSU

Customer comment

z/OS V1 5694-A01

3

   
CICS TS for OS/390 V2 5697-E93

2

   
IBM Enterprise Cobol for z/OS and OS/390 V3 5655-G53

3

   

 

Detailed Data Collection

LPAR Name

System ID

Input Data Start

Input Data End

Report %

Customer Comment

BC1B BC1B 02 Aug 2012 – 09:00 01 Sep 2012 – 23:45

98.6%

 
BC2A BC2A 02 Aug 2012 – 13:03 01 Sep 2012 – 23:48

98.1%

 
BC3A BC3A 03 Aug 2012 – 08:03 01 Sep 2012 – 23:48

95.5%

 
CPC   02 Aug 2012 – 09:00 01 Sep 2012 – 23:48

98.6%

 

 

Other information

WARNING: This SubCapacity or FullCapacity Report has been submitted late. The deadline for report submission is the 9th calendar day of the month. If you provided an explanation as a “General Comment”, your explanation will be reviewed, however, if an exception for a SubCapacity report is not granted to accept the late report, MSUs for all products will be set at Full Machine Capacity for this Reporting Period. You will be notified if the exception is not approved.
Please contact your local IBM Representative if you need further assistance.

For recurring charge (MLC) products, the data supplied in this report will be used to adjust the billable MSUs in inventory for all MLC Products listed under the MLC Product Name column on this report. In accordance with our Agreement, IBM will treat a change in product licensed capacity as an order. If the MSUs have changed since the last report, software billing based on inventory MSUs will increase or decrease accordingly.

This report is prepared by the System z customer identified above (“Customer”) or its authorized designee, and such Customer is solely responsible for the contents and accuracy of this report. Specifically, IBM makes no representations or warranties regarding the contents or accuracy of this report. Any questions concerning this report should be directed to the customer.

Check this box if you would like an e-mail receiptCheck this box if you would like an e-mail receiptCheck this box if you would like to include recipients from your distribution list in the e-mail distribution.Select the “Modify Distribution List” button (below) to add or modify recipients on your distribution list
NOTE: The distribution list will be in effect for the current session only. It will not be saved after you log off.Back                                          Save as draft                           Modify Distribution List        Submit

– Click on Submit:

The following screen appears:

Submit your current SCRT or FCRT data

You can select any system not yet submitted by ‘clicking’ on its number. You will have the opportunity to update your sub-capacity or full-capacity information before submitting it. After each report submission has been confirmed, the status field for that system will change to ‘Submitted’.

Systems

System                 

Customer               

Customer name  

    Status                                                

Time stamp

83-6093F 644164000 xxxxxxxxxxxxx Submitted          9Nov2012 08:51 UTC

           6. Confirmation Report  from IBM/LMS for the received SCRT report

Subject: SCRT Report has been submitted for System 2066-0A1 83-6093F – Reporting Period 2 Oct, 2012 – 1 Nov, 2012

 * * * * * * * * * * * * * * * * * * *

*  PLEASE DO NOT REPLY TO THE SENDER OF THIS E-MAIL !                                                             *

*  IT WAS SENT FROM A SERVICE MACHINE.                                                                            *

* * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * *

 Thank you for the Sub-Capacity report for the reporting period of 2 Oct, 2012 – 1 Nov, 2012 which was submitted on

9 Nov, 2012 08:51 UTC. via LMS Web

 Software Charges for the reporting period will apply beginning 1 December 2012.

 Please note that this e-mail serves as confirmation that the subject Sub-Capacity Report (SCRT Report) has been successfully submitted.

 Attached is the full copy of your report. Please retain this information for your records. Copies of this LMS Confirmation Receipt are also available via the LMS Archive Retrieval function.

 If you need further assistance please contact your local IBM representative.

 ___________________________________________________________________________________________________________________

 Control number                    1352390527011 2066-0A1 83-6093F

 Customer/Submitter information

Submitter name              Submitter e-mail                                 Submitter phone

Customer number

 Machine details

Machine type and model      Machine serial number                            Machine rated capacity

 Tool information

Tool release                Reporting period

21.1.0                      2 Oct, 2012 – 1 Nov, 2012 inclusive (31 days)

 % Data Collected for z/OS  99%

 Product summary information

MLC Product name      Product ID Tool MSU                Customer MSU            Customer comment Footnotes

z/OS V1               5694-A01   3

 CICS TS for OS/390 V2 5697-E93   2

 IBM Enterprise Cobol  5655-G53   3

for z/OS and OS/390

V3

 Detailed Data Collection

LPAR Name             System ID  Input Data Start        Input Data End          Report %         Customer Comment

BC1B                  BC1B       02 Oct 2012 – 00:00 UTC 01 Nov 2012 – 23:49 UTC 99.7%

BC2A                  BC2A       02 Oct 2012 – 00:03 UTC 01 Nov 2012 – 23:49 UTC 99.5%

BC3A                  BC3A       02 Oct 2012 – 00:03 UTC 01 Nov 2012 – 23:49 UTC 99.5%

CPC                              02 Oct 2012 – 00:00 UTC 01 Nov 2012 – 23:49 UTC 99.7%

For recurring charge (MLC) products, the data supplied in this report will be used to adjust the billable MSUs in  inventory for all MLC Products listed under the MLC Product Name column on this report. In accordance with our  Agreement, IBM will treat a change in product licensed capacity as an order. If the MSUs have changed since the  last report, software billing based on inventory MSUs will increase or decrease accordingly.

 This report is prepared by the System z customer identified above (“Customer”) or its authorized designee, and  such Customer is solely responsible for the contents and accuracy of this report. Specifically, IBM makes no  representations or warranties regarding the contents or accuracy of this report. Any questions concerning this  report should be directed to the customer.

           7. BC2A/90  – SMF old save  files backup, delete, restore

(backup on tape  BC2A/SMF previous  SMF summary files, delete the  old ones and restore from tape if necessary)

               7.1.  BC2A/90 – SMF old save  files backup

Job   BKPSMF02 /BC2A.ZOS140.OPER.LIB(BKPSMF02)/ –  backup on tape CB0344/BC2A  – Capacity (10Mb) – BC2A.BKPKCI08.SMF.D180612.D020712 –  label=(x,sl) – x is the  next saved file number  – last x=5 next x=6

 //BACKUP   EXEC PGM=ADRDSSU

//SYSOUT   DD   SYSOUT=*

//SYSPRINT DD   SYSOUT=*

//SYSUDUMP DD   SYSOUT=*

//DEPHSTR  DD   DSN=BC2A.BKPKCI08.SMF.D180612.D020712,

//         DCB=(KCI01.DMNSNTAP.MODEL.DCB,

//         RECFM=U,LRECL=0,BLKSIZE=32760,

//         DSORG=PS),VOL=SER=CB0344,

//         UNIT=(300,,DEFER),

//         LABEL=(1,SL),DISP=(NEW,CATLG,KEEP)

//SYSIN    DD   *

   DUMP    –

   OUTDDNAME(DEPHSTR) –

   DATASET(INCLUDE ( –

   KCI08.SMFD1806      –      

                        

– 1 file –  LABEL=(1,SL):

KCI08.SMFD1806

KCI08.SMFD0207

…………………………………………….

– Last file: LABEL=(5,SL) :   19% full

KCI08.SMF.D051112 – SMF source on 2 disk volumes

KCI08.SMFR.D051112 – SMF source on one disk volume  to repare

KCI08.SMFRF.D051112 – SMF repared fixed   output – keep for the next month SMF report (includes 02 day of the month)

KCI08.SMFRF2.D051112

KCI08.SMFRFB.D051112

KCI08.SMFRFB2.D051112

           7.2. BC2A/90 – SMF delete old saved  files

 – Job  DELSMF02 /BC2A.ZOS140.OPER.LIB.CICS10(DELSMF02)/– delete old files            (saved  KCI08.SMFRF.D051112 – contains 02.11.2012 for  SMFEXTR7/12.2012)

 //CSDEFINE EXEC PGM=IDCAMS

//SYSOUT   DD SYSOUT=*

//SYSPRINT DD SYSOUT=*

//SYSUDUMP DD SYSOUT=*

//SYSIN    DD *

   PARM MARGINS(1 80)

   DEL KCI08.D1806   

 Deleted old:

 KCI08.SMF.D051112

KCI08.SMFR.D051112

KCI08.SMFRF2.D051112

KCI08.SMFRFB.D051112

KCI08.SMFRFB2.D051112

               7.3.  BC2A/90 – SMF restore  old saved  files

 – Job RESMF02/BC2A.ZOS140.OPER.LIB(RESMF02)/ –  Restore from tape CB0344/BC2A  – Capacity (10Mb)  with  DSN= BC2A.BKPKCI08.SMF.D180612.D020712 the SMF file KCI08.SMFD1806      on LABEL=(1,sl) as file KCI08.SMF.D180612 if needed

 

//DFDSS    EXEC PGM=ADRDSSU,REGION=0M,TIME=1440 PARM=’TYPRUN=NORUN’

//SYSPRINT DD  SYSOUT=*

//TAPE     DD  DSN=BC2A.BKPKCI08.SMF.D180612.D020712,DISP=(NEW,CATLG),

//         VOL=SER=CB0344,UNIT=(300,,DEFER),

//         DCB=(KCI01.DMNSNTAP.MODEL.DCB,

//         RECFM=U,LRECL=0,BLKSIZE=32760,

//         DSORG=PS),LABEL=(1,SL)       or        (2,SL)

//SYSIN    DD  *

   RESTORE –

   DS(INC(      –

          KCI08.SMFD1806      –

   )) –

   INDDNAME(TAPE) –

   RENAMEU (KCI08.SMFD1806,KCI08.SMF.D180612) –

           8. BC3A/92  – SMF old save  files backup, delete, restore

(backup on tape  BC3A/SMF previous  SMF summary files, delete the  old ones and restore from tape if necessary)

               8.1.  BC3A/92 – SMF old save  files backup

Job   BKPSMF02 /BC2A.ZOS140.OPER.LIB(BKPSMF02)/ –  backup on tape CB0449/BC3A  – Capacity (10Mb) – DSN= BC3A.SMFEXTR.FEB8.FEB88 –  label=(x,sl) – x is the  next saved file number  – last x=5 next x=6

– 1 file –  LABEL=(1,SL):

HLQ.SMFEXTR.FEB8

HLQ.SMFEXTR.FEB88

…………………………………………….

– Last file: LABEL=(3,SL) :   13% full

KCI08.SMF.D051112 – SMF source

KCI08.SMFR.D051112 – SMF source renamed bc2a  to bc3a  – keep for the next month

                8.2. BC3A/92 – SMF delete old saved  files

 – Job  DELSMF02 /BC2A.ZOS140.OPER.LIB.CICS10(DELSMF02)/– delete old files            (saved  KCI08.SMFR.D051112 – contains 02.11.2012 for  SMFEXT8/12.2012)

KCI08.SMF.D030912

KCI08.SMF.D031012

KCI08.SMF.D240812

KCI08.SMFR.D030912

KCI08.SMFR.D031012

KCI08.SMFR.D240812

                8.3.  BC3A/92 – SMF restore  old saved  files

 – Job RESMF02/BC2A.ZOS140.OPER.LIB(RESMF02)/ –  Restore from tape CB0449/BC2A  – Capacity (10Mb)  with  DSN= BC3A.SMFEXTR.FEB8.FEB88 the SMF file KCI08.SMF.D030912   on LABEL=(2,sl) as file KCI08.SMF.D030912R if needed .

           9. BC1B/93  – SMF old save  files backup, delete, restore

(backup on tape  BC1B/SMF previous  SMF summary files, delete the  old ones and restore from tape if necessary)

               9.1.  BC1B/93 – SMF old save  files backup

– Job BKPSMF02 /BC1B.ZOS140.OPER.LIB(BKPSMF02)/   –  backup on tape cb0394/BC1B – Capacity (10Mb) dsn= BC1B.SMFDUMPW.D270712.D020812  –  label=(x,sl) – x is the  next saved file number  – last x=3 next x=4

 – 1 file –  LABEL=(1,SL):

SMFDUMPW.D270712

SMFDUMPW.D020812

……………………………..

– Last file: LABEL=(3,SL) :   6% full

SMFDUMPW.D051112   – keep for the next month SMF report (includes 02 day of the month)

                9.2.  BC1B/93 – SMF delete old saved  files

– Job DELSMF02 /BC1B.ZOS140.OPER.LIB(DELSMF02)/   – delete old files

SMFDUMPW.D270712

SMFDUMPW.D020812

……………………………………..

–       Keep the last file: SMFDUMPW.D051112 – necessary for the next month SMF report

(includes 02 day of the month)

                9.3.  BC1B/93 – SMF restore  old saved  files

 – Job RESMF02 /BC1B.ZOS140.OPER.LIB(RESMF02)/   – Restore from tape CB0394 with  DSN= BC1B.SMFDUMPW.D270712.D020812 the SMF file SMFDUMPW.D030912 on LABEL=(2,sl) as file SMFDUMPW.D030912 on vol=SP0659 if needed.